|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Applications q Industrial OEM Equipment q Off-Road Equipment q Hydraulic Systems q Compressor Control q HVAC/R Equipment q Industrial Engines q Industrial Refrigeration Benefits s Solid Stability for Confident Installations s Exceptional EMI/RFI Performance Prevents False System Shutdown s NEMA-4/IP-65 Certified (206) for Use in Harsh Environments s Rugged Design Withstands High Shock/Vibration Applications s Versatile Package Design Provides JIT Delivery s Miswiring Protection Makes for Confident Installation s User Accessible Zero and Span Adjustment Guaranteed 3-day shipment for 5 pieces in Ranges 25-5000 PSIG!* *Standard configurations only. Visit Setra Online: http://www.setra.com Certified ISO 9001 800-257-3872 Models 206/207 Specifications Performance Data Accuracy RSS (at constant temperature) Non-Linearity, (BFSL) 25 psig range Hysteresis Non-Repeatability Thermal Effects Compensated Range F (C) Zero Shift %FS/100F (%FS/50C) Span Shift %FS/100F (%FS/50C) Warm-up Shift Response Time Long Term Stability * Electrical Data (Voltage) 0.13% FS 0.1% FS 0.2% FS 0.08% FS 0.02% FS -4 to +176 (-20 to +80) 1.0 (0.9) 1.5 (1.4) 0.1% FS Total 5 milliseconds 0.5% FS/1 YR Circuit Excitation Output* Output Impedance Power Consumption 3-Wire (Exc, Out, Com) 12 to 28 VDC, Reverse Excitation Protected 0.1 to 5.1 VDC** 100 ohms <0.15 watts (approx. 5mA @ 24 VDC) S * Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater. **Zero output factory set to within 25mV. **Span (Full Scale) output factory set to within 50mV. etra's Model 206/207 Series industrial pressure transducers are some of the most rugged and most reliable sensors available. Time after time, these transducers prove to be superior to competitive brands and technologies in the most critical test of all -- the field application test! Most pressure transducers seem alike in specification comparisons and even quick bench test analysis; however, the difference becomes obvious in the actual application. Setra's robust capacitive design exhibits its resistance to environmental effects such as shock, vibration, temperature and EMI/RFI. In addition, the 206 meets NEMA-4 and IP65 environmental protection ratings. With 0.5% FS/1 Year long term stability, the 206 is reliable as well as rugged. To achieve this level of performance, Setra engineers combined a fundamentally simple but highly accurate and repeatable stainless steel capacitive sensor design and a custom ASIC based circuit. This high level output system is packaged in a welded stainless steel housing with versatility to accommodate a variety of pressure fitting and electrical connector options. Every 206/207 transducer is assembled and calibrated in product-specific workcells. This means that technical experience and high quality standards are part of every transducer. When it comes to a product to rely on - choose the Model 206/ 207. When it comes to a company to trust - choose Setra - an ESOP (Employee Owned) company. Electrical Data (Current) Circuit 2-Wire 4 to 20 mA** Output* External Load 0 to 800 ohms Minimum supply voltage (VDC) = 9 + 0.02 x (Resistance of receiver plus line). Maximum supply voltage (VDC) = 30 + .004 x (Resistance of receiver plus line). *Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load. **Zero output factory set to within 0.08mA. **Span (Full Scale) output factory set to within 0.16mA. * RSS of Non-Linearity, Non-Repeatability and Hysteresis. Environmental Data Temperature Operating1 F (C) Storage F (C) Acceleration Shock* Vibration** -40 to +260 (-40 to +125) -65 to +260 (-55 to +125) 10 g maximum2 200g operating 20g 50 - 2000 Hz Note 1: The high temperature limit of the Model 206 cable is 200F (95C). Note 2: Shift in output reading <0.05 psi/g typical; pressure port axis only. *Mil-Std. 202, Method 213B, Cond. C **Mil-Std. 202, Method 204, Cond. C Pressure Media Liquids and gases compatible with 17-4 PH Stainless Steel.* *Note: Hydrogen not recommended for use with 17-4 PH Stainless Steel. Physical Description Case Pressure Fitting Stainless Steel 1/4" NPT external (G1/4A or M14 x 1.5 also available on Model 206) Through cable (206) Via zero screw (207) 2 ft. multiconductor cable (206) 3 screw terminal block (207) Top External Access 6 ounces Vent Electrical Connection Zero/Span Adjustments Weight (approx.) Specifications subject to change without notice. Note: Setra quality standards are based on ANSI-Z540-1. The calibration of this product is NIST traceable. U.S. Patent No. 3859575; 4054833 PSIG Ranges Gauge Pressure 0-25 0-50 0-100 0-250 0-500 0-1000 0-3000 0-5000 0-10,000 Bar Ranges 206 only Burst Pressure 500 750 1000 2000 3000 5000 7500 10,000 20,000 Proof Pressure 100 150 300 500 1000 2000 4500 7500 12,500 Gauge Pressure 1.6 4.0 6.0 10 16 25 40 60 100 160 250 400 700 Proof Pressure 6 10 18 30 32 50 80 120 200 250 380 600 800 Burst Pressure 32 50 60 80 130 170 240 300 400 500 550 800 1350 Gauge Pressure: Pressure measured relative to ambient atmospheric pressure. Referred to as pounds per square inch (gauge) or psig. Proof Pressure: The maximum pressure that may be applied without changing performance beyond specifications ( 0.5% FS zero shift). Burst Pressure: The maximum pressure that may be applied to the positive pressure port without rupturing the sensing element. Available Options (Minimum Quantities for Certain Options Apply. Consult a Setra Applications Engineer.) Mechanical Options 550 560 562 563 564 655 803-825 865 Hirchmann Electrical Connector Type GSA 3000N (206 only) 7/16-20 SAE (External) Fitting 1/8" NPT (External) Fitting #4 Male Face Seal #4 Female Face Seal Top Mounted Bayonet Connector (206 only) Up to 25 feet of cable can be supplied (206 only). Specify cable length when ordering (i.e. 805 for 5 ft. cable). Consult factory for cables longer than 25 feet. NEMA 4 Weather Proof Enclosure (207 only) Electrical Options 602 603 608 901 904 911 1 to 5 VDC Output 1 to 6 VDC Output 0.1 to 10.1 VDC Output 10 Point Calibration Certificate Cleaning for Oxygen Service Etched Metal Stainless Steel Tags Feature Options Outline Drawings Cable with Conduit Version CONDUIT FITTING 1/2" NPT 2.13 54.0 1.16 29.5 7/8" HEX SPAN 206 C206 19/32 ACROSS FLATS ZERO Cable Version 0.44 11.1 2.00 50.8 ZERO SPAN 2.00 50.8 2.00 50.8 2.00 50.8 0.78 19.8 7/16-20 SAE PRESSURE FITTING 0.36 9.1 IN MM 0.75 0.50 19.1 12.7 3/4" HEX 1/4"-18 NPT PRESSURE PORT Hirschmann Connector 0.82 20.8 206 HIRSCHMANN CONNECTOR ZERO 207 Terminal Version TERMINAL STRIP SPAN ZERO SPAN RADIUS 0.77 19.6 0.57 REF. 14.5 2.00 50.8 0.48 12.0 207 2.00 50.8 2.00 50.8 1.50 38.1 2.00 50.8 .06 1.6 1.50 38.1 1.00 25.4 0.50 12.7 3/4" HEX 1/4"-18NPT PRESSURE PORT 1.80 REF. 45.7 3/4" HEX 1/4"-18NPT PRESSURE PORT 0.80 0.50 20.3 12.7 Ordering Information Example: Order as Model 206, 100 PSIG, Option #550 for a Model 206 100 PSIG Gauge Pressure Range with a Hirschmann Electrical Connector. While we provide application assistance on all Setra products, both personally and through our literature, it is up to the customer to determine the suitability of the product in the application. 159 Swanson Road, Boxborough, MA 01719/Tel: 978-263-1400; Toll Free: 800-257-3872; Fax: 978-264-0292; email: sales@setra.com SSP206/207 Rev.E 09/21/99 |
Price & Availability of 20710000PSIG |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |